Distal Femoral Fractures

Overview

  • Bimodal, high energy in the young and low energy in osteoporotic elderly
  • Often periprosthetic around knee replacements
  • AO/OTA extra-articular, partial articular and complete articular types
  • Look for a coronal Hoffa fragment on CT
  • Lateral locking plate, retrograde nail or distal femoral replacement
  • Aim for articular reduction, restored length, alignment and rotation, and early mobilisation

Presentation by Dr Rekha Ganeshalingam

Distal Femoral Fractures by Dr Rekha Ganeshalingam from Orthofracs on Vimeo.

Classification

AO/OTA 33

TypeDescription
AExtra-articular
BPartial articular
CComplete articular

Original publication Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and Dislocation Classification Compendium-2018. J Orthop Trauma. 2018;32 Suppl 1:S1-S170.

  • B3 is the coronal plane Hoffa fracture, more often of the lateral condyle

Su periprosthetic

TypeDescription
IProximal to the femoral component
IIOriginating at the proximal end of the component
IIIAny part distal to the upper edge of the anterior flange

Original publication Su ET, DeWal H, Di Cesare PE. Periprosthetic femoral fractures above total knee replacements. J Am Acad Orthop Surg. 2004;12(1):12-20.

Lewis and Rorabeck

TypeDescription
IUndisplaced, prosthesis intact
IIDisplaced, prosthesis intact
IIILoose or failing prosthesis regardless of displacement

Original publication Rorabeck CH, Taylor JW. Classification of periprosthetic fractures complicating total knee arthroplasty. Orthop Clin North Am. 1999;30(2):209-14.

Investigations

  • CT for all intra-articular fractures, since Hoffa fragments are easily missed
  • In periprosthetic fractures assess component fixation, open or closed box design and bone stock

Management

  • Deforming forces give shortening, varus and apex posterior angulation from gastrocnemius
  • Hoffa fragments need perpendicular lag or headless screws
  • Lateral locking plate with a long working length, as stiff constructs cause non-union
  • Retrograde nail for extra-articular, simple articular and open box periprosthetic fractures
  • Nail plate or dual plating allows early elderly weight bearing
  • Distal femoral replacement for comminuted fractures in poor bone or a loose component
  • Revision arthroplasty for Rorabeck III with adequate bone stock

Complications

  • Metaphyseal non-union with stiff lateral plates
  • Valgus, rotational and recurvatum malunion
  • Knee stiffness
  • One-year mortality in the elderly similar to hip fracture

Reviewed by Professor Phong Tran, Head of Orthopaedic Surgery, Western Health. Last updated 10 October 2026.